Control Relays
Current and voltage monitors both ac and dc controls circuits,pump and level control relays battery voltage under over protection, speed control, frequency monitor.

Most products carry recognised approvals including UL, CUL, CSA, VDE.....
To download the product specifications, click on the symbol
or the product type number.
View product datasheet using
Adobe Acrobat Reader
Get Adobe Acrobat Reader
45 Series   DIN Rail Mtg
Click to enlarge
DIMS: (mm) H.78 W.45 D.99
Type No
45050
45051
45OVR
45UVR
45UCR
45OCR
45150
45UFR
45OFR
45TCR New product
45200
45175
45205
Function Over Voltage Under & Over Voltage Over Voltage Under Voltage Under Current Over Current Over Current Under Frequency Over Frequency PT100 Temperature Control Thermistor Under Speed Load Sharing
  - - - - - - - - - (2 or 3-wire PT100 - DIN 43760) - - -
Time Delay (from fault) 0.1-3S 0.1-10S ˜200mS ˜200mS 0.2-10S 0.2-10S 0.1-3S ˜200mS ˜200mS 200mS 50mS 0.5-30S/M 2S (to help)
  - - - - - - 0.1-10S (on delay) - - - - - -
Hysteresis 5-50% < 2% 1-15% 1-15% ˜5% ˜5% 5-50% 0.3-3Hz 0.3-3Hz 0.5 - 20% - - -
Latch User Selectable No No No No No User Selectable No No No User Selectable User Selectable No
Output SPDT Relay SPDT Relay DPDT Relay DPDT Relay DPDT Relay DPDT Relay SPDT Relay DPDT Relay DPDT Relay SPDT Relay, 0 - 10V* (Analogue) SPDT Relay SPDT Relay 2 x SPNO Relays
Output Rating 10A @ 250VAC 10A @ 250VAC 8A @ 250VAC 8A @ 250VAC 6A @ 250VAC 6A @ 250VAC 10A @ 250VAC 8A @ 250VAC 8A @ 250VAC 8A @ 250VAC (Relay) 10A @ 250VAC 10A @ 250VAC 10A @ 250VAC
Supply Voltage Un 24, 110, 230VAC 24/115/230VAC (selectable) 110, 230VAC 110, 230VAC 110, 230, 400VAC 110, 2320, 400VAC 24, 110, 230VAC 110, 230, 400VAC 110, 230, 400VAC 24V DC 24VDC & 24, 110, 230VAC 24, 110, 230VAC 24, 110, 230, 400VAC
  - - - - - - - - - 24/110, 24/230V AC (Dual) - - -
Integral Transformer Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes (not DC) Yes Yes Yes
Monitoring Range Y2: 0.5-10VAC/DC Under trip 87-110% of Un 100-125% of Un 75-100% of Un 0-80% of 5A (In) 40-120% of 5A (In) Y2: 5-100mA AC/DC 40-60, 50-70Hz 40-60, 50-70Hz -50 to +300 deg C (5 ranges) - - -
  Y3: 3-60VAC/DC Over trip 90-113% of Un - - - - Y3: 50mA-1A AC/DC - - - - - -
  Y4: 30-600VAC/DC - - - - - Y4: 500mA-10A AC/DC - - * Analogue output relative to set point or measured temperature - - -

M1 Series   DIN Rail & Surface Mtg
Click to enlarge
DIMS: (mm) H.89 W.17.5 D.59
Type No
M1CVR New product
M1BVR
M1IRT
M1DRT
M1MFR
M1UVR
M1TVR
Function Under & Over Voltage Battery Voltage Alarm Mains Restoration Mains Restoration Mains Failure DC Under Voltage Under Voltage Timed
  (Single phase) - Auto Restart (Interval) Auto Restart - - (Delayed Restart)
Time Delay (from fault) 0.2 - 10S (adjustable) 1-30S - - ˜100mS - 100mS
  (No delay if supply is <70% of Un) - - - - - -
Hysteresis ˜2% of trip level ˜5% ˜5% ˜5% - - ˜2%
Latch No No No No No - -
Output SPDT Relay SPDT Relay SPDT Relay SPDT Relay SPDT Relay SPDT Relay SPDT Relay
Output Rating 8A @ 250VAC (AC1) 8A @ 250VAC 8A @ 250VAC 8A @ 250VAC 8A @ 250VAC - -
Supply Voltage Un 24, 110, 115, 220, 230, 240V AC 12 to 24VDC 24, 110, 115, 230VAC 24, 110, 115, 230VAC 110 to 230VAC 24, 48 VDC 220VAC
  - - - - - - -
Integral Transformer No No No No No - -
Monitoring Range 70 - 130% of Un 75-125% of Un 80% of Un 80% of U 85-115% of U - -
  Under adjustment: 75-95% of Un - (under voltage) (under voltage) (under voltage) - -
  Over adjustment: 105-125% of Un - - - - - -

B1 Series   11 Pin Plug-In
Click to enlarge
DIMS: (mm) H.80 W.40 D.92
Type No
B1UVR
B1OVR
B1CVR
B1UCS New product
B1OCS New product
B1UFZ
B1OFZ
B1LR
Function Under Voltage Over Voltage Under & Over Voltage Under Current Over Current Under Frequency Over Frequency Logic (Flip Flop)
  - - - - - - - -
Time Delay (from fault) ˜1S ˜1S 0.1-10S ˜1S ˜1S ˜1S ˜1S -
  - - - - - - - -
Hysteresis ˜1% ˜1% < 2% ˜1% ˜1% ˜1% ˜1% -
Latch No No No No No No No -
Output SPDT Relay SPDT Relay SPDT Relay SPDT Relay SPDT Relay SPDT Relay SPDT Relay DPDT Relay
Output Rating 8A @ 250VAC 8A @ 250VAC 10A @ 250VAC 8A @ 250VAC 8A @ 250VAC 8A @ 250VAC 8A @ 250VAC 8A @ 250VAC
Supply Voltage Un 12, 48VAC/DC, 24VDC 12, 48VAC/DC, 24VDC 24, 115, 230VAC 12, 48VAC/DC, 24VDC 12, 48VAC/DC, 24VDC 12, 48VAC/DC, 24VDC 12, 48VAC/DC, 24VDC 110, 240VAC
  24, 110, 220/240VAC 24, 110, 220/240VAC - 24, 110, 220/240VAC 24, 110, 220/240VAC 24, 110, 220/240VAC 24, 110, 220/240VAC -
Integral Transformer 110, 220/240V only 110, 220/240V only Yes 110, 220/240V only 110, 220/240V only 110, 220/240V only 110, 220/240V only Yes
Monitoring Range 3.5-50V or 5-70VDC 3.5-50V or 5-70VDC Under: 83-98% of Un 4-20mA DC 4-20mA DC 35-70Hz 35-70Hz -
  35-500VAC or 35-500VAC or Over: 102-117% of Un 0.35-5A AC 0.35-5A AC - - -
  50-700VDC 50-700VDC - 0.5-7.5 DC 0.5-7.5 DC - - -

M3 Series   DIN Rail & Surface Mtg
Click to enlarge
DIMS: (mm) H.89 W.35 D.59
Type No
M3CVR/2 New product
M3MVR
M3MCR
M3LS2 New product
M3LS3 New product
M3VRC
Function Under & Over Voltage Multi Function Multi Function Load Sharing Load Sharing DC Under & Over Voltage
  (Single phase) Voltage Current (2 Control Contacts) (3 Control Contacts) -
Time Delay (from fault) 0.2 - 10S (adjustable) 100mS or 1S 100mS or 1S <1Sec energise/de-energise <1Sec energise/de-energise -
  (No delay if supply is <70% of Un) - - 2 Sec (to help) - -
Hysteresis ˜2% of trip level 2% or 10% of set level 2% or 10% of set level - - -
Latch No Switch Selectable Switch Selectable No No -
Output DPDT Relay SPDT Relay SPDT Relay 2 x SPNO Relays 3 x SPNO Relays 2xDPNO Relay
Output Rating 8A @ 250VAC (AC1) 8A @ 250VAC 8A @ 250VAC 5A @ 250VAC 5A @ 250VAC -
Supply Voltage Un 24, 110, 115, 220, 230, 240V AC 18-240VAC, 12-240VDC 18-240VAC, 12-240VDC 24, 110, 230, 400V AC 24, 110, 230, 400V AC 24, 48VDC
  - - - - - -
Integral Transformer No Yes Yes Yes Yes -
Monitoring Range 70-130% of Un 1. 1 to 26.5VAC/DC 1. 20mA to 500mA, AC/DC - - -
  Under adjustment: 75-95% of Un 2. 10 to 265VAC/DC 2. 200mA to 5A AC/DC - - -
  Over adjustment: 105-125% of Un Switch Selectable Switch Selectable - - -

70 Series   DIN Rail & Surface Mtg
Click to enlarge
DIMS: (mm) H.70 W.100 D.114
Type No
70CVR
Function Under & Over Voltage
  -
Time Delay (from fault) 200mS
  -
Hysteresis 1-15%
Latch No
Output 2 x DPDT Relays
Output Rating 8A @ 250VAC
Supply Voltage Un 110, 230VAC
  -
Integral Transformer Yes
Monitoring Range Under trip 75-100% of Un
  Over trip 100-125% of Un
  -

P48 Series   Panel Mtg / Plug-In
Click to enlarge
DIMS: (mm) H.48 W.48 D.103
Type No
P48SRR
P48SMP
P48TR
Function Shaft Rotation Shaft Rotation Tachometer
  - - -
Time Delay (from fault) 1-30, 2-60S 1-30, 2-60S -
  - - -
Hysteresis - - -
Latch - - -
Output SPDT Relay SPDT Relay SPDT Relay
Output Rating 8A @ 250VAC 8A @ 250VAC 8A @ 250VAC
Supply Voltage Un 24, 110, 220/240VAC 24, 110, 220/240VAC 110, 220/240VAC
  - - -
Integral Transformer Yes Yes Yes
Monitoring Range - - 200-10, 000 rpm
  - - -
  - - -

D2TVR
Click to enlarge
DIMS: (mm) H.86 W.171 D.41
Type No
D2TVR
Function Under Voltage Timed
  (Delayed Restart)
Time Delay (from fault) 100mS
  -
Hysteresis ˜2%
Latch -
Output SPDT Relay
Output Rating -
Supply Voltage Un 220VAC
  -
Integral Transformer -
Monitoring Range -
  -
  -

CT
Click to enlarge
Type No
CT New product
Function Current Transformers
  -
Time Delay (from fault) -
  -
Hysteresis -
Latch -
Output 5A Secondary
Output Rating -
Supply Voltage Un -
  -
Integral Transformer -
Monitoring Range CT10 (10/5A), CT60 (60/5A)
  CT100 (100/5A), CT200 (200/5A)
  CT400 (400/5A)

             